Normative reference

Oil resistance

EN 50363-10-2
UL 1581

Flame resistance

UL VW-1
IEC 60332-1-2
UL FT1

Toxicity

Halogen free
EN 60754-1

UL-CSA standard

80°C – 300 V
Style 20233
AWM I/II A/B

Non-hygroscopic

IEC 60811-402

Abrasion resistance

ASTM D 4060

Resistance to weathering

Cold: EN 60811-1-4
Ozone: EN 50396 Art. 8.1.3
UV: HD605 Part. 2.4.20
Microbes: VDE 0282/10
Mud: NEK 606

 

Family Code

OMDS08

Share datasheet

Description

Multipair single shielded cables, PUR jacket, for dynamic application max 600 m/min

Application

Technical data

Minimum bending radius

6.5 x cable diameter

Maximum speed

600 m/min

Maximum acceleration

60 m/s2

Cycles

10 million

Conductor

Flexible tinned copper

Insulation

Polypropylene

Colour code

TAB CP2

Shield

On pair – tinned copper wire braid O.C. ≥ 80%

Sheath inner conductors

Polyolefin
colour: black RAL 9005

Outer sheath

PUR
colour: green RAL 6018

Service temperature

-40°C +80°C

Storage temperature

-50°C +80°C

Service voltage

300 V (UL/CSA)

Dielectric strength

4 kV x 5 min. according to EN 50395 Cl. 10.3

Insulation resistance

≥ 1.0 GΩ x km @ 20°C according to EN 50395 Cl. 8.1

Torsion

± 30°C/1000 mm

 

Item Numbers

Codice articoloAWG/MCMFormazione AWG/KcmilsFormazione CEFormazione n° × tipo di fibraRiferimento OEMFormazione (n° × mmq)ColoreDiametro (mm)Cu (kg/km)Tiro
OMDS08/300-MC3 x (2 x 0.25 SK)8.334
OMDS08/301-MC4 x (2 x 0.25 SK)9.045
OMDS08/302-MC5 x (2 x 0.25 SK)10.356
OMDS08/303-MC6 x (2 x 0.25 SK)11.768
OMDS08/304-MC9 x (2 x 0.25 SK)13.6101
OMDS08/310-MC3 x (2 x 0.34 SK)9.441
OMDS08/311-MC4 x (2 x 0.34 SK)10.055
OMDS08/312-MC5 x (2 x 0.34 SK)11.269
OMDS08/313-MC6 x (2 x 0.34 SK)12.683
OMDS08/314-MC9 x (2 x 0.34 SK)15.7125