Normative reference
EN 50363-4-1
UL VW-1
IEC 60332-1-2
UL FT1
90°C – 1000 V
UL-AWM Style 21179
AWM I/II A/B
IEC 61800-3-4-5
IEC 60811-402
Description
Hybrid servo motor cables, for dynamic application max 300 m/min
Application
Technical data
| Minimum bending radius | 6.5 x cable diameter |
| Maximum speed | 300 m/min |
| Maximum acceleration | 20 m/s2 |
| Cycles | ≥ 5 million |
| Conductor | DATA – Tinned flexible copper |
| Insulation | DATA – Special Polyolefin – grey, pink, violet, yellow, white/green, brown/green |
| Separator | Easy stripper tape |
| Shield | Tinned copper wire braid O.C. ≥ 85% |
| Sheath | PVC – TM5 |
| Service temperature | +5°C +80°C |
| Storage temperature | -30°C +80°C |
| Service voltage | 1000 V (UL/CSA) Uo/U 0.6/1 kV (IEC) |
| Insulation resistance | ≥ 1.0 GΩ x km @ 20°C according to EN 50395 Cl. 8.1 |
| Dielectric strength | 4 kV x 5 min. according to EN 50395 Cl. 10.3 |
| Codice articolo | AWG/MCM | Formazione AWG/Kcmils | Formazione CE | Formazione n° × tipo di fibra | Riferimento OEM | Formazione (n° × mmq) | Colore | Diametro (mm) | Cu (kg/km) | Tiro |
|---|---|---|---|---|---|---|---|---|---|---|
| OMDS10/560 | (4G1.5 + 1x(2x0.75) + 1x(2x0.30 + 2x2x0.15)) | 13.0 | 165 | |||||||
| OMDS10/561 | (4G2.5 + 1x(2x0.75) + 1x(2x0.30 + 2x2x0.15)) | 14.2 | 210 | |||||||
| OMDS10/562 | (4G4.0 + 1x(2x0.75) + 1x(2x0.30 + 2x2x0.15)) | 16.5 | 285 |