Normative reference
IEC 50363-4-1
UL 1581
IEC 60332-1-2
UL FT1
UL VW1
UR AWM 90°C -1000 V
Style UL 21179
CSA – AWM I/II A/B 90°C -1000 V
IEC 61800-3-4-5
IEC 60811-402
Description
Oil resistant shielded cables for power supply brushless motors, PVC jacket, for dynamic application max 300 m/min
Application
Technical data
| Minimum bending radius | 7.5 x cable diameter |
| Maximum speed | 300 m/min |
| Maximum acceleration | 20 m/s2 |
| Cycles | 5 million |
| Conductor | Flexible bare copper class 6 |
| Insulation | Special Polypropylene |
| Colour code | Power: U/L1/C/L+ |
| Separator | Easy stripper tape |
| Shield | Tinned copper wire braid O.C. ≥ 85% |
| Sheath | PVC – TM5 |
| Service temperature | +5°C +90°C |
| Storage temperature | -30°C +90°C |
| Service voltage | 1000 V (UL/CSA) Uo/U 0.6/1.0 kV (IEC) |
| Dielectric strength | 4 kV x 5 min. according to EN 50395 Cl. 10.3 |
| Insulation resistance | ≥ 1.0 GΩ x km @ 20°C according to EN 50395 Cl. 8.1 |
| Torsion | ± 30°C/1000 mm |
| Codice articolo | AWG/MCM | Formazione AWG/Kcmils | Formazione CE | Formazione n° × tipo di fibra | Riferimento OEM | Formazione (n° × mmq) | Colore | Diametro (mm) | Cu (kg/km) | Tiro |
|---|---|---|---|---|---|---|---|---|---|---|
| OMDS02/100-MC | 6FX5008-1BB11PLUS | (3+T) x 1.5 | 8.9 | 94 | ||||||
| OMDS02/101-MC | 6FX5008-1BB21PLUS | (3+T) x 2.5 | 10.6 | 142 | ||||||
| OMDS02/102-MC | 6FX5008-1BB31PLUS | (3+T) x 4 | 11.7 | 200 | ||||||
| OMDS02/103-MC | 6FX5008-1BB41PLUS | (3+T) x 6 | 14.4 | 310 | ||||||
| OMDS02/104-MC | 6FX5008-1BB51 | (3+T) x 10 | 18.0 | 486 | ||||||
| OMDS02/105-MC | 6FX5008-1BB61 | (3+T) x 16 | 22.0 | 770 | ||||||
| OMDS02/106-MC | 6FX5008-1BB25 | (3+T) x 25 | 26.3 | 1167 | ||||||
| OMDS02/107-MC | 6FX5008-1BB35 | (3+T) x 35 | 30.0 | 1540 | ||||||
| OMDS02/108-MC | 6FX5008-1BB50 | (3+T) x 50 | 35.5 | 2247 | ||||||
| OMDS02/109-MC | (3+T) x 70 | 42.0 | 3245 | |||||||
| OMDS02/110-MC | (3+T) x 95 | 46.0 | 4055 |