Normative reference

Oil resistance

VDE 0472 Part. 803/B
IRM 902 – ASTM n. 2
HD 505.2.1 Part. 10
UL 1581 Cl. 43 (only 60°C)
IEC 60811-2-1

Flame resistance

IEC 60332-1
EN 50265-2-1
UL 1581
UL VW-1
CSA FT1
VDE 0472 Part. 804 B

No fire spread

IEC 60332.3

UL-CSA standard

UL 1581
UL 758
CSA C.22 n. 210.2

 

Family Code

ORMH0

Share datasheet

Description

Multiconductor oil resistant shielded cables, UL-CSA-HAR (H05VVC4V5-F) approved

Application

Power supply & signalling Machine tools Wood working machinery Marble working machinery

Technical data

Minimum bending radius

≥ 15 x cable diameter

Conductor

Flexible bare copper according to:
UL 1581 Tab. 20.1
CEI 20-29 Class 5
IEC 60228 class 5
VDE 0295 Class 5

Insulation

PVC according to VDE – CEI – IEC – UL-CSA

Colour code

Black numbered + yellow/green

Inner sheath

PVC compound

Shield

Tinned copper C.O. ≥ 80%

Sheath

PVC O.R. (HAR HD 21.13.S1) – VDE 0207 Part. 5 – UL-CSA
colour: grey RAL 7001

Approved

IEMMEQU

Service voltage

UL AWM 90°C – 600/1000 V
CSA AWM 90°C – 600/1000 V
HAR 300/500 V

Dielectric strength

3000 V

Insulation resistance

≥ 200 MΩ x km

Storage temperature

-40°C +90°C

Service temperature

-15°C +70°C HAR
-15°C +90°C UL-CSA

Construction specifications

UL 758/1581 and CSA C.22.2 n. 210.2-M90 – FT1
HAR-IEMMEQU: HD 21.13.S1(*) – CEI 20-20

 

Item Numbers

Codice articoloAWG/MCMFormazione AWG/KcmilsFormazione CEFormazione n° × tipo di fibraRiferimento OEMFormazione (n° × mmq)ColoreDiametro (mm)Cu (kg/km)Tiro
20 AWG
ORMH01012x0.58.235
ORMH01023G0.58.642
ORMH01034G0.59.153
ORMH01045G0.59.962
ORMH01057G0.511.577
ORMH010612G0.514.3129
ORMH010719G0.517.6176
ORMH010825G0.519.5215
ORMH010934G0.520.8269
ORMH011037G0.522.9295
ORMH011141G0.523.8338
ORMH011252G0.525.8367
ORMH011361G0.529.4480
18 AWG
ORMH02012x18.849
ORMH02023G19.659
ORMH02034G110.071
ORMH02045G111.183
ORMH02057G113.0110
ORMH020612G115.5184
ORMH020719G119.5253
ORMH020825G121.2371
ORMH020934G123.8461
ORMH021037G125.6495
ORMH021141G126.7530
ORMH021252G128.8620
ORMH021361G133.0770
16 AWG
ORMH03002x1.59.866
ORMH03013G1.510.576
ORMH03024G1.511.388
ORMH03035G1.512.7110
ORMH03047G1.514.9174
ORMH030512G1.518.0268
ORMH030619G1.522.8400
ORMH030725G1.524.9510
ORMH030834G1.528.4656
ORMH030937G1.530.0688
ORMH031041G1.531.0700
ORMH031152G1.533.5820
14 AWG
ORMH04002x2.511.686
ORMH04013G2.512.1105
ORMH04024G2.513.6148
ORMH04035G2.514.9182
ORMH04047G2.517.8261
ORMH040512G2.521.2406
ORMH040619G2.526.7560

(*) According to HD21 valid for: Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Holland, Norway, Portugal, Spain, Sweden, Switzerland, Great Britain, United States and Canada.

x = no yellow/green conductor

N.B. HAR standards include cables up to 2.5 mm2 (14 AWG) section