Normative reference

No flame spread

CEI EN 60332-1-2

Oil resistance

EN 50363-10-2
EN 60811-404 (24 Std./100°C)

Corrosive Gas & Halogen

IEC 60754-2
IEC 60754-1

Printing

H07BQ-F (formation) Eca (n° ord.)
(year) Made in Italy (mt)

U.V. Resistance

EN 50289-4-17 Method A

CPR

Class: Eca
Notified Body: 2479

Non-hygroscopic

EN 60811-402

 

Family Code

ORPURLS

Description

Multiconductor control cables, PUR - HAR jacket

Application

Power supply Industrial and agricultural machines Tools connection (drills, saws) Machine tools Electrical panels

Technical data

Minimum bending radius

4 x cable diameter, static application

Conductor

Flexible copper, class 5
CEI EN 60228 (CEI 20-29) – IEC 60228
Conductors stranded in concentric layers

Insulation

EPR rubber, EI6

Colour code

Two-core: blue, brown
Three-core: yellow/green, blue, brown or brown, black, grey
Four-core: yellow/green, brown, black, grey or blue, brown, black, grey
Five-core: yellow/green, blue, brown, black, grey or blue, brown, black, grey, black

Sheath

PUR quality TMPU LS0H
colour: orange RAL 2003

Service temperature

-60°C +90°C

Nominal voltage

450/750 V

Testing voltage

3000 V

RoHS directive

2011/65/UE

 

Item Numbers

Codice articoloAWG/MCMFormazione AWG/KcmilsFormazione CEFormazione n° × tipo di fibraRiferimento OEMFormazione (n° × mmq)ColoreDiametro (mm)Cu (kg/km)Tiro
ORPURLS1,0/022x19.018
ORPURLS1,5/022x1.59.827
ORPURLS2,5/022x2.511.645
ORPURLS4,0/022x413.772
ORPURLS6,0/022x615.1108
ORPURLS10/022x1019.9180
ORPURLS16/022x1622.8288
ORPURLS1,0/033G19.527
ORPURLS1,5/033G1.510.441
ORPURLS2,5/033G2.512.468
ORPURLS4,0/033G414.5108
ORPURLS6,0/033G616.3162
ORPURLS10/033G1021.4270
ORPURLS16/033G1624.7432