Normative reference

No flame spread

CEI EN 60332-1-2

Oil resistance

CEI 20-34/0-1
ASTM n.2
IRM 902

Corrosive Gas & Halogen

CEI EN 50267-2-1

Printing

FLEX-OIL O.R. plus 600/1000 V
(formation) Eca – O.R. CEI 20-34
FLAME RETARDANT CEI 60332-1-2
(n°ord.) (year) (mt)

U.V. Resistance

EN 50289-4-17 Method A

CPR

Class: Eca
Notified Body: 2479

Non-hygroscopic

EN 60811-402

 

Family Code

ORSH11

Description

Multiconductor flame retardant shielded power cables, with oil resistant jacket (CEI EN 60332-1-2)

Application

Power supply & signalling Machine tools Wood working machinery Restricted movements

Technical data

Minimum bending radius

8 x cable diameter, static application
15 x cable diameter, dynamic application (unsupported)

Maximum chain length

3 m

Maximum speed

30 m/min

Conductor

Flexible copper, class 5
CEI EN 60228 (CEI 20-29) – IEC 60228
Conductors stranded in concentric layers

Insulation

PVC R2 according to CEI EN 50363 (CEI 20-11)

Colour code

Black numbered + yellow/green

Shield

Copper wire braid O.C. ≥ 80%

Sheath

PVC RZ according to CEI EN 50363 (CEI 20-11)
colour: grey RAL 7001
UV and OIL resistant

Service temperature

Static application: -30°C +70°C

Nominal voltage

0,6/1 kV

Testing voltage

4000 V

Insulation resistance

≥ 100 MΩ x km

 

Item Numbers

Codice articoloAWG/MCMFormazione AWG/KcmilsFormazione CEFormazione n° × tipo di fibraRiferimento OEMFormazione (n° × mmq)ColoreDiametro (mm)Cu (kg/km)Tiro
ORSH1105A4G1.511.881
ORSH1110A4G2.512.9122
ORSH1120A4G415.1186
ORSH1121A4G616.4262
ORSH1122A4G1019.8440
ORSH1123A4G1622.5674
ORSH1124A4G2526.61050
ORSH11254G3529.51431
ORSH11264G5034.52043
ORSH11274G7038.42727

Note: Available different number of conductors on demand